<?xml version="1.0"?>
<?xml-stylesheet type="text/css" href="https://wiki.openmod-initiative.org/skins/common/feed.css?303"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
		<id>https://wiki.openmod-initiative.org/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Austeja+Dapkute</id>
		<title>wiki.openmod-initiative.org - User contributions [en]</title>
		<link rel="self" type="application/atom+xml" href="https://wiki.openmod-initiative.org/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Austeja+Dapkute"/>
		<link rel="alternate" type="text/html" href="https://wiki.openmod-initiative.org/wiki/Special:Contributions/Austeja_Dapkute"/>
		<updated>2026-06-01T00:12:01Z</updated>
		<subtitle>User contributions</subtitle>
		<generator>MediaWiki 1.19.7</generator>

	<entry>
		<id>https://wiki.openmod-initiative.org/wiki/EA-PSM_Electric_Short_Circuit</id>
		<title>EA-PSM Electric Short Circuit</title>
		<link rel="alternate" type="text/html" href="https://wiki.openmod-initiative.org/wiki/EA-PSM_Electric_Short_Circuit"/>
				<updated>2019-05-07T13:39:14Z</updated>
		
		<summary type="html">&lt;p&gt;Austeja Dapkute: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Model&lt;br /&gt;
|Full_Model_Name=EA-PSM Electric Short Circuit&lt;br /&gt;
|Acronym=EA-PSM Electric Short Circuit&lt;br /&gt;
|author_institution=JSC Energy Advice&lt;br /&gt;
|contact_email=info@energyadvice.lt&lt;br /&gt;
|website=http://www.energyadvice.lt/en/&lt;br /&gt;
|source_download=http://www.energyadvice.lt/en/&lt;br /&gt;
|logo=EA-PSM HnE-02.png&lt;br /&gt;
|text_description=EA-PSM Electric Short Circuit calculation model allows to get immediate results of three-phase, phase-to-phase, phase-to-isolated neutral and phase-to-grounded neutral short circuit currents. Calculations of the model are verified in accordance with IEC 60909 standard.&lt;br /&gt;
|open_source_licensed=No&lt;br /&gt;
|model_source_public=No&lt;br /&gt;
|Link to source=http://www.energyadvice.lt/en/electrical-engineering-software-for-plant/&lt;br /&gt;
|data_availability=all&lt;br /&gt;
|open_future=No&lt;br /&gt;
|modelling_software=Java&lt;br /&gt;
|processing_software=Java, JavaFX&lt;br /&gt;
|GUI=Yes&lt;br /&gt;
|Transfer (Electricity)=Distribution, Transmission&lt;br /&gt;
|Storage (Gas)=No&lt;br /&gt;
|Storage (Heat)=No&lt;br /&gt;
|georegions=Global, European Union, Lithuania, Turkey, Poland, India&lt;br /&gt;
|georesolution=global, continents, nations&lt;br /&gt;
|network_coverage=transmission, distribution, AC load flow, DC load flow&lt;br /&gt;
|math_modeltype=Optimization, Simulation&lt;br /&gt;
|is_suited_for_many_scenarios=No&lt;br /&gt;
|montecarlo=Yes&lt;br /&gt;
|Model input file format=No&lt;br /&gt;
|Model file format=No&lt;br /&gt;
|Model output file format=No&lt;br /&gt;
}}&lt;/div&gt;</summary>
		<author><name>Austeja Dapkute</name></author>	</entry>

	<entry>
		<id>https://wiki.openmod-initiative.org/wiki/EA-PSM_Electric_Short_Circuit</id>
		<title>EA-PSM Electric Short Circuit</title>
		<link rel="alternate" type="text/html" href="https://wiki.openmod-initiative.org/wiki/EA-PSM_Electric_Short_Circuit"/>
				<updated>2019-05-06T10:28:05Z</updated>
		
		<summary type="html">&lt;p&gt;Austeja Dapkute: Created page with &amp;quot;{{Model |Full_Model_Name=EA-PSM Electric Short Circuit |author_institution=JSC Energy Advice |website=http://www.energyadvice.lt/en/ |source_download=http://www.energyadvice.l...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Model&lt;br /&gt;
|Full_Model_Name=EA-PSM Electric Short Circuit&lt;br /&gt;
|author_institution=JSC Energy Advice&lt;br /&gt;
|website=http://www.energyadvice.lt/en/&lt;br /&gt;
|source_download=http://www.energyadvice.lt/en/&lt;br /&gt;
|logo=EA-PSM HnE-02.png&lt;br /&gt;
|text_description=EA-PSM Electric Short Circuit calculation model allows to get immediate results of three-phase, phase-to-phase, phase-to-isolated neutral and phase-to-grounded neutral short circuit currents. Calculations of the model are verified in accordance with IEC 60909 standard.&lt;br /&gt;
|open_source_licensed=No&lt;br /&gt;
|model_source_public=No&lt;br /&gt;
|Link to source=http://www.energyadvice.lt/en/&lt;br /&gt;
|data_availability=all&lt;br /&gt;
|open_future=No&lt;br /&gt;
|GUI=No&lt;br /&gt;
|Storage (Gas)=No&lt;br /&gt;
|Storage (Heat)=No&lt;br /&gt;
|georegions=Global, European Union, Lithuania, Turkey, Poland, India&lt;br /&gt;
|georesolution=global, continents, nations&lt;br /&gt;
|network_coverage=transmission, distribution, AC load flow, DC load flow&lt;br /&gt;
|math_modeltype=Optimization, Simulation&lt;br /&gt;
|is_suited_for_many_scenarios=No&lt;br /&gt;
|montecarlo=Yes&lt;br /&gt;
|Model input file format=No&lt;br /&gt;
|Model file format=No&lt;br /&gt;
|Model output file format=No&lt;br /&gt;
}}&lt;/div&gt;</summary>
		<author><name>Austeja Dapkute</name></author>	</entry>

	<entry>
		<id>https://wiki.openmod-initiative.org/wiki/EA-PSM_Electric_Arc_Flash</id>
		<title>EA-PSM Electric Arc Flash</title>
		<link rel="alternate" type="text/html" href="https://wiki.openmod-initiative.org/wiki/EA-PSM_Electric_Arc_Flash"/>
				<updated>2019-04-30T06:04:18Z</updated>
		
		<summary type="html">&lt;p&gt;Austeja Dapkute: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Model&lt;br /&gt;
|Full_Model_Name=EA-PSM Electric Arc Flash&lt;br /&gt;
|Acronym=EA-PSM Electric Arc Flash&lt;br /&gt;
|author_institution=JSC Energy Advice&lt;br /&gt;
|contact_email=info@energyadvice.lt&lt;br /&gt;
|website=http://www.energyadvice.lt/en&lt;br /&gt;
|source_download=http://www.energyadvice.lt/en&lt;br /&gt;
|logo=EA-PSM HnE-02.png&lt;br /&gt;
|text_description=EA-PSM Arc flash model can be used to calculate arc flash incident energy, flash boundary, both arc and fault currents, safe working distance. Calculations are validated in accordance with IEEE 1584 standard. It is possible to choose from different equipment types and calculate incident energy at any selected distance.&lt;br /&gt;
|open_source_licensed=No&lt;br /&gt;
|model_source_public=No&lt;br /&gt;
|Link to source=http://www.energyadvice.lt/en/electrical-engineering-software-for-plant/&lt;br /&gt;
|data_availability=all&lt;br /&gt;
|open_future=No&lt;br /&gt;
|modelling_software=Java&lt;br /&gt;
|processing_software=Java, JavaFX&lt;br /&gt;
|GUI=Yes&lt;br /&gt;
|Transfer (Electricity)=Distribution, Transmission&lt;br /&gt;
|Storage (Gas)=No&lt;br /&gt;
|Storage (Heat)=No&lt;br /&gt;
|georegions=Global, European Union, Lithuania, Turkey, Poland, India&lt;br /&gt;
|georesolution=global, continents, nations&lt;br /&gt;
|network_coverage=transmission, distribution, AC load flow, DC load flow&lt;br /&gt;
|math_modeltype=Optimization, Simulation&lt;br /&gt;
|is_suited_for_many_scenarios=Yes&lt;br /&gt;
|montecarlo=No&lt;br /&gt;
|Model input file format=No&lt;br /&gt;
|Model file format=No&lt;br /&gt;
|Model output file format=No&lt;br /&gt;
}}&lt;/div&gt;</summary>
		<author><name>Austeja Dapkute</name></author>	</entry>

	<entry>
		<id>https://wiki.openmod-initiative.org/wiki/EA-PSM_Electric_Arc_Flash</id>
		<title>EA-PSM Electric Arc Flash</title>
		<link rel="alternate" type="text/html" href="https://wiki.openmod-initiative.org/wiki/EA-PSM_Electric_Arc_Flash"/>
				<updated>2019-04-29T12:25:41Z</updated>
		
		<summary type="html">&lt;p&gt;Austeja Dapkute: Created page with &amp;quot;{{Model |Full_Model_Name=EA-PSM Electric Arc Flash |Acronym=EA-PSM Electric Arc Flash |author_institution=JSC Energy Advice |contact_email=info@energyadvice.lt |website=http:/...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Model&lt;br /&gt;
|Full_Model_Name=EA-PSM Electric Arc Flash&lt;br /&gt;
|Acronym=EA-PSM Electric Arc Flash&lt;br /&gt;
|author_institution=JSC Energy Advice&lt;br /&gt;
|contact_email=info@energyadvice.lt&lt;br /&gt;
|website=http://www.energyadvice.lt/en&lt;br /&gt;
|source_download=http://www.energyadvice.lt/en&lt;br /&gt;
|logo=EA-PSM HnE-02.png&lt;br /&gt;
|text_description=EA-PSM Arc flash model can be used to calculate arc flash incident energy, flash boundary, both arc and fault currents, safe working distance. Calculations are validated in accordance with IEEE 1584 standard. It is possible to choose from different equipment types and calculate incident energy at any selected distance.&lt;br /&gt;
|open_source_licensed=No&lt;br /&gt;
|model_source_public=Yes&lt;br /&gt;
|Link to source=http://www.energyadvice.lt/en/electrical-engineering-software-for-plant/&lt;br /&gt;
|data_availability=all&lt;br /&gt;
|open_future=Yes&lt;br /&gt;
|GUI=No&lt;br /&gt;
|Transfer (Electricity)=Distribution, Transmission&lt;br /&gt;
|Storage (Gas)=No&lt;br /&gt;
|Storage (Heat)=No&lt;br /&gt;
|georegions=Global, European Union, Lithuania, Turkey, Poland, India&lt;br /&gt;
|georesolution=global, continents, nations&lt;br /&gt;
|network_coverage=transmission, distribution, AC load flow, DC load flow&lt;br /&gt;
|math_modeltype=Optimization, Simulation&lt;br /&gt;
|is_suited_for_many_scenarios=Yes&lt;br /&gt;
|montecarlo=No&lt;br /&gt;
|Model input file format=No&lt;br /&gt;
|Model file format=No&lt;br /&gt;
|Model output file format=No&lt;br /&gt;
}}&lt;/div&gt;</summary>
		<author><name>Austeja Dapkute</name></author>	</entry>

	<entry>
		<id>https://wiki.openmod-initiative.org/wiki/File:EA-PSM_HnE-02.png</id>
		<title>File:EA-PSM HnE-02.png</title>
		<link rel="alternate" type="text/html" href="https://wiki.openmod-initiative.org/wiki/File:EA-PSM_HnE-02.png"/>
				<updated>2019-04-29T11:53:37Z</updated>
		
		<summary type="html">&lt;p&gt;Austeja Dapkute: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Austeja Dapkute</name></author>	</entry>

	</feed>