|
|
(18 intermediate revisions by one user not shown) |
Line 3: |
Line 3: |
| |Acronym=Maon | | |Acronym=Maon |
| |author_institution=Maon GmbH | | |author_institution=Maon GmbH |
− | |authors=Mihail Ketov, Fabian Breitkreutz, Yash Patel, Sangeetha Kadarkarai, Hajar Mouchrik, Nicolai Schmid, Dariush Wahdany, Kaan Gecü, Ömer Bilgin, Esmanur Eryilmaz, Ali Baran Gündüz, Mark Schäfer, Kai Strunz, Albert Moser | + | |authors=Mihail Ketov, Fabian Breitkreutz, Yash Patel, Sangeetha Kadarkarai, Hajar Mouchrik, Nicolai Schmid, Dariush Wahdany, Kaan Gecü, Ömer Bilgin, Ali Baran Gündüz, Anton Kucherenko, Söhnke Hartmann, Kai Strunz, Albert Moser |
| |contact_persons=Dr. Mihail Ketov | | |contact_persons=Dr. Mihail Ketov |
| |contact_email=info@maon.eu | | |contact_email=info@maon.eu |
− | |website=https://cloud.maon.eu/handbook | + | |website=https://maon.eu |
− | |source_download=https://apis.cloud.maon.eu
| + | |
| |logo=Maon Colors Frontpage Header.png | | |logo=Maon Colors Frontpage Header.png |
− | |text_description=Maon is a market simulation for fundamental electricity, gas, and emission market analysis. It forecasts the facility-wise quarter-hourly dispatch of all supply and demand in whole Europe. | + | |text_description=Maon is a market simulation for fundamental electricity, gas, and emission market analysis. It forecasts the facility-wise quarter-hourly dispatch of all supply and demand in whole Europe. Further, it can predict capacities and uncertainties of generators, interconnectors, storages, and consumers. |
| | | |
| Web browsers provide access to the data management, simulation, and analysis environment. It enables high-speed, high-resolution, and large-scale foresights. Scenarios can be parameterized by multiple users at the same time, calculated by one click, and collaboratively visually analyzed. | | Web browsers provide access to the data management, simulation, and analysis environment. It enables high-speed, high-resolution, and large-scale foresights. Scenarios can be parameterized by multiple users at the same time, calculated by one click, and collaboratively visually analyzed. |
| | | |
− | Users get support by work-leveraging parameterization tools, comprehensive quality checks, and interactive visualizations. Maon provides not only results like prices, dispatches, and exchanges, but also revenues, costs, utilizations, capture rates, price distributions, and thousands of other results. | + | Users get support by work-leveraging parameterization tools, comprehensive quality checks, and interactive visualizations. Maon provides not only results like prices, dispatches, and capacities, but also capture rates, costs, price distributions, revenues, utilizations, and thousands of other results. |
| |Support=commercial | | |Support=commercial |
− | |User documentation=https://cloud.maon.eu/handbook | + | |User documentation=https://docs.cloud.maon.eu/ |
− | |Code documentation=https://cloud.maon.eu/handbook | + | |Code documentation=https://docs.cloud.maon.eu/ |
| |Source of funding=private | | |Source of funding=private |
| |Number of developers=10 | | |Number of developers=10 |
Line 50: |
Line 49: |
| |Observation period=Less than one month, Less than one year, More than one year | | |Observation period=Less than one month, Less than one year, More than one year |
| |math_modeltype=Optimization, Simulation, Other, Agent-based | | |math_modeltype=Optimization, Simulation, Other, Agent-based |
− | |math_objective=Minimization of operational costs for electricity spot and frequency reserve markets considering emission caps | + | |math_objective=Minimization of dispatch and investment cost |
| |deterministic=Monte Carlo, preprocessing or sensitivity | | |deterministic=Monte Carlo, preprocessing or sensitivity |
| |is_suited_for_many_scenarios=Yes | | |is_suited_for_many_scenarios=Yes |
Line 57: |
Line 56: |
| |computation_time_minutes=1000 | | |computation_time_minutes=1000 |
| |computation_time_hardware=high performance computing cluster | | |computation_time_hardware=high performance computing cluster |
− | |computation_time_comments=8760 coupled hours for full European region with spot, FCR, aFRR, mFRR, emission, renewable, thermal, hydro, battery, CHP, PtG, DSR, FBMC, AHC, HVDC and on-off decision model, but without facility-wise aggregations | + | |computation_time_comments=dispatch for 8760 coupled hours in full European region with spot, FCR, aFRR, mFRR, emission, renewable, thermal, hydro, battery, CHP, PtG, DSR, FBMC, AHC, HVDC and on-off decision model, but without facility-wise aggregations |
− | |citation_references=Maon GmbH, Handbook, https://cloud.maon.eu/handbook. | + | |citation_references=Maon GmbH, Documentation, https://docs.cloud.maon.eu. |
| |report_references=https://maon.eu/publications | | |report_references=https://maon.eu/publications |
| |Interfaces=Front-end at https://cloud.maon.eu and APIS at https://apis.cloud.maon.eu | | |Interfaces=Front-end at https://cloud.maon.eu and APIS at https://apis.cloud.maon.eu |